subbiah kannan profile photo 1 on Tal

subbiah kannan

Engineering Manager- Protection & control / Primary Design

Chennai

12+ years of work experience

Larsen & Toubro
May 20233 yrs 7 mosPresent

Chennai, Tamil Nadu, India

Reviewing protection, SCS and GIS vendor documents including technical data sheet, protection base design , detail design and SCS configuration • Interface engineering between various components like GIS – Protection, Transformer monitoring system- Transformer, Neutral grounding resistor, 11kV Switchgear-Protection panel. • Preparation of SLD, PLD, Schematics, Specification, Design basis, Interconnection Cable Schedule and SCS signal list • HT & LT cables, CT, VT, Battery Charger, UPS, ACDB, DCDB and Transformer sizing calculation Battery sizing: IEEE485-Battery sizing for Lead Acid, IEEE1115-Battery sizing for Nickel Cadmium Cable Sizing & selection: IEC60502-1 from 1kV to 3kV, IEC60502-2 from 6kV to 30kV,IEC 60840 above 30kV to 150kV,IEC 60364-5-52 for LV cables, EN 50618-2014 Electric cables for photovoltaic system System Earthing: IEEE80-2013 Guide for safety in AC substation Grounding Transformer: IEC 60076-1 CT & VT sizing: Current Transformer: IEC 61869-2 (Additional Requirement of current transformer) Voltage Transformer: IEC 61869-3 (Additional Requirement of Inductive Voltage Transformer) IEC 61869-5 (Additional Requirement of Capacitive Voltage Transformer) Emergency Diesel Generator sizing: IEC 60034-1
Raptors Trading & Contracting
Aug 20228 mosMar 2023

Qatar

Estimation & testing of equipment's & Relays Power system studies through ETAP(Short circuit studies, Load Flow analysis, Arc flash analysis, Relay co-ordination).
EMCO QATAR
Sep 20175 yrsAug 2022

Doha, Doha, Qatar

Planning & Schedule through Primavera. IN QATAR,MMUP registered engineer (Reg-no-19642) IN QATAR,QATAR CIVEL DEFENSE DEPARTMENT(QCD LICENSED) ENGINEER EXPERIENCE IN QATAR: Working in GTC/829/2016 as Testing Engineer (Outsourcing of Kahramaa Distribution Protection works) from Sep’ 2017-till date. Pilot Wire Protection Relay Commissioning in live 11KV Indoor substations. Routine maintenance of 11kv substations. Pre-commissioning of 11kv Indoor substations. REF documents check for Approvals.
GK POWER EXPERTISE PVT LTD
Jun 20133 yrs 11 mosApr 2017

India

Relay Testing & Commissioning SAS co-ordination with SAS Engineer Scheme Modification & Retrofitting EXPERIENCE IN INDIA: Testing & Commissioning of: Protection (Switchyard & CRP) System Conventional & Numerical Relays from 0.415 to 400kV Line Distance Protection (from 66 to 765kV) Line Differential Protection (Up to 132kV) Transformer & Feeder Protection Switch Gear Panels, Power Control Center and Motor Control Center Bus Bar Protection (220 and 400kV)

subbiah’s AI Stack

antigravity
antigravity
gemini
gemini
ChatGPT
ChatGPT

Education

Anna University Chennai

Batchelor of engineering, Electrical and Electronics Engineering

Anna University Chennai

20094 yrs2013

Join subbiah and 10k+ other professionals on

Tal Boss

Tal is the app where bosses meet engineers & builders directly, without middlemen

Download Tal Boss

subbiah kannan on Tal

Headline

Engineering Manager- Protection & control / Primary Design

About

9 years 9 months over all experience in testing & commissioning and maintenance activity at various Transmission & Distribution substations which involves the testing of numerical relays, equipment’s like CT, VT, Transformer (up to 1.6MVA) like overall commissioning & maintenance of switchgear panels & Control protection panels, follow up team planning, scheduling, co-ordinate with customer Power system studies like short circuit, Load flow, Relay co-ordination through ETAP

Location

Chennai

AI stack

antigravity

gemini

ChatGPT

Work experience

Engineering Manager at Larsen & Toubro, May 2023 - Present · 3 yrs 7 mos, Chennai, Tamil Nadu, India, Reviewing protection, SCS and GIS vendor documents including technical data sheet, protection base design , detail design and SCS configuration • Interface engineering between various components like GIS – Protection, Transformer monitoring system- Transformer, Neutral grounding resistor, 11kV Switchgear-Protection panel. • Preparation of SLD, PLD, Schematics, Specification, Design basis, Interconnection Cable Schedule and SCS signal list • HT & LT cables, CT, VT, Battery Charger, UPS, ACDB, DCDB and Transformer sizing calculation Battery sizing: IEEE485-Battery sizing for Lead Acid, IEEE1115-Battery sizing for Nickel Cadmium Cable Sizing & selection: IEC60502-1 from 1kV to 3kV, IEC60502-2 from 6kV to 30kV,IEC 60840 above 30kV to 150kV,IEC 60364-5-52 for LV cables, EN 50618-2014 Electric cables for photovoltaic system System Earthing: IEEE80-2013 Guide for safety in AC substation Grounding Transformer: IEC 60076-1 CT & VT sizing: Current Transformer: IEC 61869-2 (Additional Requirement of current transformer) Voltage Transformer: IEC 61869-3 (Additional Requirement of Inductive Voltage Transformer) IEC 61869-5 (Additional Requirement of Capacitive Voltage Transformer) Emergency Diesel Generator sizing: IEC 60034-1

Testing & Estimation Engineer at Raptors Trading & Contracting, Aug 2022 - Mar 2023 · 8 mos, Qatar, Estimation & testing of equipment's & Relays Power system studies through ETAP(Short circuit studies, Load Flow analysis, Arc flash analysis, Relay co-ordination).

Testing and commissioning engineer at EMCO QATAR, Sep 2017 - Aug 2022 · 5 yrs, Doha, Doha, Qatar, Planning & Schedule through Primavera. IN QATAR,MMUP registered engineer (Reg-no-19642) IN QATAR,QATAR CIVEL DEFENSE DEPARTMENT(QCD LICENSED) ENGINEER EXPERIENCE IN QATAR: Working in GTC/829/2016 as Testing Engineer (Outsourcing of Kahramaa Distribution Protection works) from Sep’ 2017-till date. Pilot Wire Protection Relay Commissioning in live 11KV Indoor substations. Routine maintenance of 11kv substations. Pre-commissioning of 11kv Indoor substations. REF documents check for Approvals.

relay testing and commissioning at GK POWER EXPERTISE PVT LTD, Jun 2013 - Apr 2017 · 3 yrs 11 mos, India, Relay Testing & Commissioning SAS co-ordination with SAS Engineer Scheme Modification & Retrofitting EXPERIENCE IN INDIA: Testing & Commissioning of: Protection (Switchyard & CRP) System Conventional & Numerical Relays from 0.415 to 400kV Line Distance Protection (from 66 to 765kV) Line Differential Protection (Up to 132kV) Transformer & Feeder Protection Switch Gear Panels, Power Control Center and Motor Control Center Bus Bar Protection (220 and 400kV)

Education

Batchelor of engineering, Electrical and Electronics Engineering, Anna University Chennai